// This example demonstrates the loggable entries originating in the OPC-UA client engine and the EasyUAClient component.
#include "stdafx.h" // Includes "QuickOpc.h", and other commonly used files
#include <atlcom.h>
#include "LogEntry.h"
namespace _EasyUAClientManagement
{
// CEasyUAClientManagementEvents
class CEasyUAClientManagementEvents : public IDispEventImpl<1, CEasyUAClientManagementEvents>
{
public:
BEGIN_SINK_MAP(CEasyUAClientManagementEvents)
// Event handlers must have the __stdcall calling convention
SINK_ENTRY(1, 1 /*DISPID_EASYUACLIENTManagementEVENTS_LOGENTRY*/, &CEasyUAClientManagementEvents::LogEntry)
END_SINK_MAP()
public:
// Event handler for the LogEntry event. It simply prints out the event.
STDMETHOD(LogEntry)(VARIANT varSender, _LogEntryEventArgs* pEventArgs)
{
_tprintf(_T("%s\n"), (LPCTSTR)CW2CT(pEventArgs->ToString));
return S_OK;
}
};
void LogEntry::Main()
{
// Initialize the COM library
CoInitializeEx(NULL, COINIT_MULTITHREADED);
{
// The management object allows access to static behavior - here, the shared LogEntry event.
_EasyUAClientManagementPtr ClientManagementPtr(__uuidof(EasyUAClientManagement));
// Hook events
CEasyUAClientManagementEvents* pClientManagementEvents = new CEasyUAClientManagementEvents();
AtlGetObjectSourceInterface(ClientManagementPtr, &pClientManagementEvents->m_libid,
&pClientManagementEvents->m_iid,
&pClientManagementEvents->m_wMajorVerNum, &pClientManagementEvents->m_wMinorVerNum);
pClientManagementEvents->m_iid = _uuidof(DEasyUAClientManagementEvents);
pClientManagementEvents->DispEventAdvise(ClientManagementPtr, &pClientManagementEvents->m_iid);
// Do something - invoke an OPC read, to trigger some loggable entries.
_EasyUAClientPtr ClientPtr(__uuidof(EasyUAClient));
ClientPtr->ReadValue(
//L"http://opcua.demo-this.com:51211/UA/SampleServer",
L"opc.tcp://opcua.demo-this.com:51210/UA/SampleServer",
L"nsu=http://test.org/UA/Data/ ;i=10853");
_tprintf(_T("Processing log entry events for 1 minute...\n"));
Sleep(60*1000);
// Unhook events
pClientManagementEvents->DispEventUnadvise(ClientManagementPtr, &pClientManagementEvents->m_iid);
}
// Release all interface pointers BEFORE calling CoUninitialize()
CoUninitialize();
}
}
// This example demonstrates the loggable entries originating in the OPC-UA
// client engine and the EasyUAClient component.
type
TClientManagementEventHandlers = class
procedure OnLogEntry(
Sender: TObject;
sender0: OleVariant;
eventArgs: _LogEntryEventArgs);
end;
// Event handler for the LogEntry event. It simply prints out the event.
procedure TClientManagementEventHandlers.OnLogEntry(
Sender: TObject;
sender0: OleVariant;
eventArgs: _LogEntryEventArgs);
begin
WriteLn(eventArgs.ToString);
end;
class procedure LogEntry.Main;
var
Client: EasyUAClient;
EvsClientManagement: TEvsEasyUAClientManagement;
ClientManagement: EasyUAClientManagement;
ClientManagementEventHandlers: TClientManagementEventHandlers;
Value: OleVariant;
begin
// The Management object allows access to static behavior - here, the
// shared LogEntry event.
EvsClientManagement := TEvsEasyUAClientManagement.Create(nil);
ClientManagement := EvsClientManagement.ComServer;
ClientManagementEventHandlers := TClientManagementEventHandlers.Create;
EvsClientManagement.OnLogEntry := @ClientManagementEventHandlers.OnLogEntry;
// Do something - invoke an OPC read, to trigger some loggable entries.
Client := CoEasyUAClient.Create;
Value := Client.ReadValue(
//'http://opcua.demo-this.com:51211/UA/SampleServer',
'opc.tcp://opcua.demo-this.com:51210/UA/SampleServer',
'nsu=http://test.org/UA/Data/ ;i=10853');
WriteLn('Processing log entry events for 1 minute...');
PumpSleep(60*1000);
end;
// This example demonstrates the loggable entries originating in the OPC-UA
// client engine and the EasyUAClient component.
type
TClientManagementEventHandlers130 = class
procedure OnLogEntry(
ASender: TObject;
sender: OleVariant;
const eventArgs: _LogEntryEventArgs);
end;
// Event handler for the LogEntry event. It simply prints out the event.
procedure TClientManagementEventHandlers130.OnLogEntry(
ASender: TObject;
sender: OleVariant;
const eventArgs: _LogEntryEventArgs);
begin
WriteLn(eventArgs.ToString);
end;
class procedure LogEntry.Main;
var
Client: OpcLabs_EasyOpcUA_TLB._EasyUAClient;
ClientManagement: TEasyUAClientManagement;
ClientManagementEventHandlers: TClientManagementEventHandlers130;
Value: OleVariant;
begin
// The management object allows access to static behavior - here, the
// shared LogEntry event.
ClientManagement := TEasyUAClientManagement.Create(nil);
ClientManagementEventHandlers := TClientManagementEventHandlers130.Create;
ClientManagement.OnLogEntry := ClientManagementEventHandlers.OnLogEntry;
ClientManagement.Connect;
// Do something - invoke an OPC read, to trigger some loggable entries.
Client := CoEasyUAClient.Create;
try
Value := Client.ReadValue(
//'http://opcua.demo-this.com:51211/UA/SampleServer',
//'https://opcua.demo-this.com:51212/UA/SampleServer/',
'opc.tcp://opcua.demo-this.com:51210/UA/SampleServer',
'nsu=http://test.org/UA/Data/ ;i=10853');
except
on E: EOleException do
begin
WriteLn(Format('*** Failure: %s', [E.GetBaseException.Message]));
//Exit;
end;
end;
WriteLn('Processing log entry events for 1 minute...');
PumpSleep(60*1000);
WriteLn('Finished.');
FreeAndNil(ClientManagement);
FreeAndNil(ClientManagementEventHandlers);
end;
// This example demonstrates the loggable entries originating in the OPC-UA client engine and the EasyUAClient component.
class ClientManagementEvents {
// Event handler for the LogEntry event. It simply prints out the event.
function LogEntry($Sender, $E)
{
printf("%s\n", $E);
}
}
// The management object allows access to static behavior - here, the shared LogEntry event.
$ClientManagement = new COM("OpcLabs.EasyOpc.UA.EasyUAClientManagement");
$ClientManagementEvents = new ClientManagementEvents();
com_event_sink($ClientManagement, $ClientManagementEvents, "DEasyUAClientManagementEvents");
// Do something - invoke an OPC read, to trigger some loggable entries.
$Client = new COM("OpcLabs.EasyOpc.UA.EasyUAClient");
try
{
$value = $Client->ReadValue(
//"http://opcua.demo-this.com:51211/UA/SampleServer",
"opc.tcp://opcua.demo-this.com:51210/UA/SampleServer",
"nsu=http://test.org/UA/Data/ ;i=10853");
}
catch (com_exception $e)
{
printf("*** Failure: %s\n", $e->getMessage());
Exit();
}
printf("Processing log entry events for 1 minute...");
$startTime = time(); do { com_message_pump(1000); } while (time() < $startTime + 60);
Rem This example demonstrates the loggable entries originating in the OPC-UA client engine and the EasyUAClient component.
' The management object allows access to static behavior - here, the shared LogEntry event.
'Public WithEvents ClientManagement1 As EasyUAClientManagement
Private Sub LogEntry_Main_Command_Click()
OutputText = ""
Set ClientManagement1 = New EasyUAClientManagement
' Do something - invoke an OPC read, to trigger some loggable entries.
Dim client As New EasyUAClient
On Error Resume Next
Dim value As Variant
value = client.ReadValue("opc.tcp://opcua.demo-this.com:51210/UA/SampleServer", "nsu=http://test.org/UA/Data/ ;i=10853")
If Err.Number <> 0 Then
OutputText = OutputText & "*** Failure: " & Err.Source & ": " & Err.Description & vbCrLf
Exit Sub
End If
On Error GoTo 0
OutputText = OutputText & "Processing log entry events for 1 minute..." & vbCrLf
Pause 60000
Set ClientManagement1 = Nothing
OutputText = OutputText & "Finished..." & vbCrLf
End Sub
' Event handler for the LogEntry event. It simply prints out the event.
Private Sub ClientManagement1_LogEntry(ByVal sender As Variant, ByVal eventArgs As OpcLabs_BaseLib.LogEntryEventArgs)
OutputText = OutputText & eventArgs & vbCrLf
End Sub
Rem This example demonstrates the loggable entries originating in the OPC-UA client engine and the EasyUAClient component.
Option Explicit
' The management object allows access to static behavior - here, the shared LogEntry event.
Dim ClientManagement: Set ClientManagement = CreateObject("OpcLabs.EasyOpc.UA.EasyUAClientManagement")
WScript.ConnectObject ClientManagement, "ClientManagement_"
' Do something - invoke an OPC read, to trigger some loggable entries.
Dim Client: Set Client = CreateObject("OpcLabs.EasyOpc.UA.EasyUAClient")
On Error Resume Next
Dim value: value = Client.ReadValue("opc.tcp://opcua.demo-this.com:51210/UA/SampleServer", "nsu=http://test.org/UA/Data/ ;i=10853")
If Err.Number <> 0 Then
WScript.Echo "*** Failure: " & Err.Source & ": " & Err.Description
WScript.Quit
End If
On Error Goto 0
WScript.Echo "Processing log entry events for 1 minute..."
WScript.Sleep 60*1000
' Event handler for the LogEntry event. It simply prints out the event.
Sub ClientManagement_LogEntry(Sender, e)
WScript.Echo e