// This example shows how to subscribe to event notifications, pull events, and display each incoming event.
using System;
using OpcLabs.EasyOpc.UA;
using OpcLabs.EasyOpc.UA.AddressSpace.Standard;
using OpcLabs.EasyOpc.UA.OperationModel;
namespace UADocExamples.AlarmsAndConditions
{
class PullEventNotification
{
public static void Main1()
{
// Define which server we will work with.
UAEndpointDescriptor endpointDescriptor =
"opc.tcp://opcua.demo-this.com:62544/Quickstarts/AlarmConditionServer";
// Instantiate the client object.
// In order to use event pull, you must set a non-zero queue capacity upfront.
var client = new EasyUAClient { PullEventNotificationQueueCapacity = 1000 };
Console.WriteLine("Subscribing...");
client.SubscribeEvent(endpointDescriptor, UAObjectIds.Server, 1000);
Console.WriteLine("Processing event notifications for 30 seconds...");
int endTick = Environment.TickCount + 30 * 1000;
do
{
EasyUAEventNotificationEventArgs eventArgs = client.PullEventNotification(2 * 1000);
if (!(eventArgs is null))
// Handle the notification event.
Console.WriteLine(eventArgs);
} while (Environment.TickCount < endTick);
Console.WriteLine("Unsubscribing...");
client.UnsubscribeAllMonitoredItems();
Console.WriteLine("Finished.");
}
// Example output (truncated):
//Subscribing...
//Processing event notifications for 30 seconds...
//[] Success
//[] Success; Refresh; RefreshInitiated
//[] Success; Refresh; (10 field results) [EastTank] 100! "The dialog was activated" @9/10/2019 8:08:23 PM
//[] Success; Refresh; (10 field results) [EastTank] 500! "The alarm was acknoweledged." @10/14/2019 4:00:13 PM
//[] Success; Refresh; (10 field results) [EastTank] 100! "The alarm was acknoweledged." @11/9/2019 9:56:23 AM
//[] Success; Refresh; (10 field results) [EastTank] 500! "The alarm was acknoweledged." @10/14/2019 4:00:17 PM
//[] Success; Refresh; (10 field results) [EastTank] 100! "The alarm severity has increased." @9/10/2019 8:09:07 PM
//[] Success; Refresh; (10 field results) [EastTank] 100! "The alarm severity has increased." @9/10/2019 8:10:09 PM
//[] Success; Refresh; (10 field results) [NorthMotor] 100! "The dialog was activated" @9/10/2019 8:08:25 PM
//[] Success; Refresh; (10 field results) [NorthMotor] 500! "The alarm was acknoweledged." @10/14/2019 4:00:02 PM
//[] Success; Refresh; (10 field results) [NorthMotor] 500! "The alarm was acknoweledged." @10/14/2019 4:00:16 PM
//[] Success; Refresh; (10 field results) [NorthMotor] 300! "The alarm severity has increased." @11/9/2019 10:29:42 AM
//[] Success; Refresh; (10 field results) [NorthMotor] 100! "The alarm severity has increased." @9/10/2019 8:09:11 PM
//[] Success; Refresh; (10 field results) [NorthMotor] 100! "The alarm severity has increased." @9/10/2019 8:10:19 PM
//[] Success; Refresh; (10 field results) [WestTank] 100! "The dialog was activated" @9/10/2019 8:08:25 PM
//[] Success; Refresh; (10 field results) [WestTank] 300! "The alarm was acknoweledged." @10/14/2019 4:00:12 PM
//[] Success; Refresh; (10 field results) [WestTank] 300! "The alarm severity has increased." @11/9/2019 10:29:42 AM
//[] Success; Refresh; (10 field results) [WestTank] 300! "The alarm was acknoweledged." @10/14/2019 4:00:04 PM
//[] Success; Refresh; (10 field results) [WestTank] 100! "The alarm severity has increased." @9/10/2019 8:08:58 PM
//[] Success; Refresh; (10 field results) [WestTank] 100! "The alarm severity has increased." @9/10/2019 8:09:48 PM
//[] Success; Refresh; (10 field results) [SouthMotor] 100! "The dialog was activated" @9/10/2019 8:08:25 PM
//[] Success; Refresh; (10 field results) [SouthMotor] 300! "The alarm severity has increased." @11/9/2019 10:29:42 AM
//[] Success; Refresh; (10 field results) [SouthMotor] 700! "The alarm was acknoweledged." @10/14/2019 4:00:21 PM
//[] Success; Refresh; (10 field results) [SouthMotor] 500! "The alarm was acknoweledged." @10/14/2019 4:00:03 PM
//[] Success; Refresh; (10 field results) [SouthMotor] 100! "The alarm severity has increased." @9/10/2019 8:09:02 PM
//[] Success; Refresh; (10 field results) [SouthMotor] 100! "The alarm severity has increased." @9/10/2019 8:09:59 PM
//[] Success; Refresh; RefreshComplete
//[] Success; (10 field results) [Internal] 500! "Raising Events" @11/9/2019 10:29:43 AM
//[] Success; (10 field results) [Internal] 500! "Events Raised" @11/9/2019 10:29:43 AM
//[] Success; (10 field results) [Internal] 500! "Raising Events" @11/9/2019 10:29:44 AM
//[] Success; (10 field results) [Internal] 500! "Events Raised" @11/9/2019 10:29:44 AM
//[] Success; (10 field results) [Internal] 500! "Raising Events" @11/9/2019 10:29:45 AM
//[] Success; (10 field results) [Internal] 500! "Events Raised" @11/9/2019 10:29:45 AM
//[] Success; (10 field results) [Internal] 500! "Raising Events" @11/9/2019 10:29:46 AM
//[] Success; (10 field results) [Internal] 500! "Events Raised" @11/9/2019 10:29:46 AM
//[] Success; (10 field results) [Internal] 500! "Raising Events" @11/9/2019 10:29:47 AM
//[] Success; (10 field results) [Internal] 500! "Events Raised" @11/9/2019 10:29:47 AM
//[] Success; (10 field results) [Internal] 500! "Raising Events" @11/9/2019 10:29:48 AM
//[] Success; (10 field results) [Internal] 500! "Events Raised" @11/9/2019 10:29:48 AM
//[] Success; (10 field results) [Internal] 500! "Raising Events" @11/9/2019 10:29:49 AM
//[] Success; (10 field results) [Internal] 500! "Events Raised" @11/9/2019 10:29:49 AM
//[] Success; (10 field results) [Internal] 500! "Raising Events" @11/9/2019 10:29:50 AM
//[] Success; (10 field results) [Internal] 500! "Events Raised" @11/9/2019 10:29:50 AM
//[] Success; (10 field results) [Internal] 500! "Raising Events" @11/9/2019 10:29:51 AM
//[] Success; (10 field results) [Internal] 500! "Events Raised" @11/9/2019 10:29:51 AM
//[] Success; (10 field results) [Internal] 500! "Raising Events" @11/9/2019 10:29:52 AM
//[] Success; (10 field results) [Internal] 500! "Events Raised" @11/9/2019 10:29:52 AM
//[] Success; (10 field results) [Internal] 500! "Raising Events" @11/9/2019 10:29:53 AM
//[] Success; (10 field results) [NorthMotor] 500! "The alarm severity has increased." @11/9/2019 10:29:53 AM
//[] Success; (10 field results) [Internal] 500! "Events Raised" @11/9/2019 10:29:53 AM
//[] Success; (10 field results) [WestTank] 500! "The alarm severity has increased." @11/9/2019 10:29:53 AM
//[] Success; (10 field results) [SouthMotor] 500! "The alarm severity has increased." @11/9/2019 10:29:53 AM
//[] Success; (10 field results) [Internal] 500! "Raising Events" @11/9/2019 10:29:54 AM
//[] Success; (10 field results) [Internal] 500! "Events Raised" @11/9/2019 10:29:54 AM
//[] Success; (10 field results) [Internal] 500! "Raising Events" @11/9/2019 10:29:55 AM
//...
}
}
# This example shows how to subscribe to event notifications, pull events, and display each incoming event.
# The QuickOPC package is needed. Install it using "pip install opclabs_quickopc".
import opclabs_quickopc
import time
# Import .NET namespaces.
from OpcLabs.EasyOpc.UA import *
from OpcLabs.EasyOpc.UA.AddressSpace.Standard import *
from OpcLabs.EasyOpc.UA.OperationModel import *
# Define which server we will work with.
endpointDescriptor = UAEndpointDescriptor('opc.tcp://opcua.demo-this.com:62544/Quickstarts/AlarmConditionServer')
# Instantiate the client object.
# In order to use event pull, you must set a non-zero queue capacity upfront.
client = EasyUAClient()
client.PullEventNotificationQueueCapacity = 1000
print('Subscribing...')
IEasyUAClientExtension.SubscribeEvent(
client,
endpointDescriptor,
UANodeDescriptor(UAObjectIds.Server),
1000)
print('Processing event notifications for 30 seconds...')
endTime = time.time() + 30
while time.time() < endTime:
eventArgs = IEasyUAClientExtension.PullEventNotification(client, 2*1000)
if eventArgs is not None:
# Handle the notification event.
print(eventArgs)
print('Unsubscribing...')
client.UnsubscribeAllMonitoredItems()
print('Finished.')
' This example shows how to subscribe to event notifications, pull events, and display each incoming event.
Imports OpcLabs.EasyOpc.UA
Imports OpcLabs.EasyOpc.UA.AddressSpace.Standard
Imports OpcLabs.EasyOpc.UA.OperationModel
Namespace AlarmsAndConditions
Friend Class PullEventNotification
Public Shared Sub Main1()
' Instantiate the client object
Dim client = New EasyUAClient()
' In order to use event pull, you must set a non-zero queue capacity upfront.
client.PullEventNotificationQueueCapacity = 1000
Console.WriteLine("Subscribing...")
client.SubscribeEvent(
"opc.tcp://opcua.demo-this.com:62544/Quickstarts/AlarmConditionServer",
UAObjectIds.Server,
1000)
Console.WriteLine("Processing event notifications for 30 seconds...")
Dim endTick As Integer = Environment.TickCount + 30 * 1000
Do
Dim eventArgs As EasyUAEventNotificationEventArgs = client.PullEventNotification(2 * 1000)
If Not eventArgs Is Nothing Then
' Handle the notification event
Console.WriteLine(eventArgs)
End If
Loop While Environment.TickCount < endTick
End Sub