QuickOPC User's Guide and Reference
SlowestAutomaticUpdateRate Property (DAAutoSubscribingParameters)



OpcLabs.EasyOpcClassicCore Assembly > OpcLabs.EasyOpc.DataAccess.Optimization Namespace > DAAutoSubscribingParameters Class : SlowestAutomaticUpdateRate Property
Slowest automatic update rate. Number of milliseconds. When the system automatically modifies the update rate of an OPC item, it never chooses a rate that is slower (has higher value) than the value of this property.
Syntax
'Declaration
 
<DataMemberAttribute()>
<DefaultValueAttribute(1800000)>
Public Property SlowestAutomaticUpdateRate As Integer
'Usage
 
Dim instance As DAAutoSubscribingParameters
Dim value As Integer
 
instance.SlowestAutomaticUpdateRate = value
 
value = instance.SlowestAutomaticUpdateRate
[DataMember()]
[DefaultValue(1800000)]
public int SlowestAutomaticUpdateRate {get; set;}
[DataMember()]
[DefaultValue(1800000)]
public:
property int SlowestAutomaticUpdateRate {
   int get();
   void set (    int value);
}
Remarks

The value must be greater than zero.

Requirements

Target Platforms: .NET Framework: Windows 10 (selected versions), Windows 11 (selected versions), Windows Server 2016, Windows Server 2022; .NET: Linux, macOS, Microsoft Windows