QuickOPC User's Guide and Reference
WriteValue(IEasyUAClient,UAEndpointDescriptor,UANodeDescriptor,Object,UAIndexRangeList) Method



OpcLabs.EasyOpcUA Assembly > OpcLabs.EasyOpc.UA Namespace > IEasyUAClientExtension Class > WriteValue Method : WriteValue(IEasyUAClient,UAEndpointDescriptor,UANodeDescriptor,Object,UAIndexRangeList) Method
The client object that will perform the operation.
Endpoint descriptor. Identifies the OPC-UA server.
Node descriptor. Identifies the node in OPC server's address space.
The value to be written.
List of index ranges for individual array dimensions.
Writes a value into an attribute an OPC server. Only the item value is written (status code and timestamps are not written). Writes value into a Value attribute of a node, specifying an endpoint descriptor, node Id, and index range list.
Syntax
'Declaration
 
<ExtensionAttribute()>
Public Overloads Shared Function WriteValue( _
   ByVal client As IEasyUAClient, _
   ByVal endpointDescriptor As UAEndpointDescriptor, _
   ByVal nodeDescriptor As UANodeDescriptor, _
   ByVal value As Object, _
   ByVal indexRangeList As UAIndexRangeList _
) As ValueTuple(Of Boolean,Boolean)
'Usage
 
Dim client As IEasyUAClient
Dim endpointDescriptor As UAEndpointDescriptor
Dim nodeDescriptor As UANodeDescriptor
Dim value As Object
Dim indexRangeList As UAIndexRangeList
Dim value As ValueTuple(Of Boolean,Boolean)
 
value = IEasyUAClientExtension.WriteValue(client, endpointDescriptor, nodeDescriptor, value, indexRangeList)

Parameters

client
The client object that will perform the operation.
endpointDescriptor
Endpoint descriptor. Identifies the OPC-UA server.
nodeDescriptor
Node descriptor. Identifies the node in OPC server's address space.
value
The value to be written.
indexRangeList
List of index ranges for individual array dimensions.
Exceptions
ExceptionDescription

A null reference (Nothing in Visual Basic) is passed to a method that does not accept it as a valid argument.

This is a usage error, i.e. it will never occur (the exception will not be thrown) in a correctly written program. Your code should not catch this exception.

The OPC UA operation has failed. This operation exception in uniformly used to allow common handling of various kinds of errors. The System.Exception.InnerException always contains information about the actual error cause.

This is an operation error that depends on factors external to your program, and thus cannot be always avoided. Your code must handle it appropriately.

Requirements

Target Platforms: .NET Framework: Windows 10 (selected versions), Windows 11 (selected versions), Windows Server 2016, Windows Server 2022; .NET: Linux, macOS, Microsoft Windows

See Also