'Declaration
Property WriteNarrowestRealType As Boolean
'Usage
Dim instance As _UAClientSessionParameters Dim value As Boolean instance.WriteNarrowestRealType = value value = instance.WriteNarrowestRealType
bool WriteNarrowestRealType {get; set;}
'Declaration
Property WriteNarrowestRealType As Boolean
'Usage
Dim instance As _UAClientSessionParameters Dim value As Boolean instance.WriteNarrowestRealType = value value = instance.WriteNarrowestRealType
bool WriteNarrowestRealType {get; set;}
If this property is false
and the type is not given explicitly, the client will attempt to write Double when the variable data type is Number.
Note that when this property is true
, the written value can lose precision!
In order to obtain or modify this parameter, in the default state (when OpcLabs.EasyOpc.UA.EasyUAClientCore.Isolated equals to false
), access OpcLabs.EasyOpc.UA.Engine.UAClientAdaptableParameters.SessionParameters property of static OpcLabs.EasyOpc.UA.EasyUAClientCore.AdaptableParameters. If you have set OpcLabs.EasyOpc.UA.EasyUAClientCore.Isolated to true
, you need to access OpcLabs.EasyOpc.UA.Engine.UAClientAdaptableParameters.SessionParameters property of OpcLabs.EasyOpc.UA.EasyUAClientCore.IsolatedParameters.
This method or property does not throw any exceptions, aside from execution exceptions such as System.Threading.ThreadAbortException or System.OutOfMemoryException.