QuickOPC User's Guide and Reference
WriteItem(IEasyDAClient,String,String,String,DAVtq) Method
Example 



OpcLabs.EasyOpcClassicCore Assembly > OpcLabs.EasyOpc.DataAccess Namespace > IEasyDAClientExtension Class > WriteItem Method : WriteItem(IEasyDAClient,String,String,String,DAVtq) Method
The client object that will perform the operation.
Name of the machine. Determines the computer on which the OPC server is located. May be an empty string, in which case the OPC server is assumed to exist on the local computer or at the computer specified for it by DCOM configuration.
Contains ProgID of the OPC server to write into.
Contains OPC item identifier.
The object containing the value, timestamp and quality to be written.
Writes into a named item in an OPC server. Value, quality and timestamp are written. Writes DAVtq into a named item using individual parameters specifying its location, and using server's canonical data type.
Syntax
'Declaration
 
<ExtensionAttribute()>
Public Overloads Shared Sub WriteItem( _
   ByVal client As IEasyDAClient, _
   ByVal machineName As String, _
   ByVal serverClass As String, _
   ByVal itemId As String, _
   ByVal vtq As DAVtq _
) 
'Usage
 
Dim client As IEasyDAClient
Dim machineName As String
Dim serverClass As String
Dim itemId As String
Dim vtq As DAVtq
 
IEasyDAClientExtension.WriteItem(client, machineName, serverClass, itemId, vtq)

Parameters

client
The client object that will perform the operation.
machineName
Name of the machine. Determines the computer on which the OPC server is located. May be an empty string, in which case the OPC server is assumed to exist on the local computer or at the computer specified for it by DCOM configuration.
serverClass
Contains ProgID of the OPC server to write into.
itemId
Contains OPC item identifier.
vtq
The object containing the value, timestamp and quality to be written.
Exceptions
ExceptionDescription

One of the arguments provided to a method is not valid.

This is a usage error, i.e. it will never occur (the exception will not be thrown) in a correctly written program. Your code should not catch this exception.

A null reference (Nothing in Visual Basic) is passed to a method that does not accept it as a valid argument.

This is a usage error, i.e. it will never occur (the exception will not be thrown) in a correctly written program. Your code should not catch this exception.

The OPC "Classic" (or OPC XML-DA) operation has failed. This operation exception in uniformly used to allow common handling of various kinds of errors. The System.Exception.InnerException always contains information about the actual error cause.

This is an operation error that depends on factors external to your program, and thus cannot be always avoided. Your code must handle it appropriately.

Remarks

The server can be local or can be remotely accessed via DCOM. Optionally, an access path can be specified or a specific data type can be requested.

Example

.NET

COM

// This example shows how to write a value, timestamp and quality into a single item.

using System;
using OpcLabs.EasyOpc.DataAccess;
using OpcLabs.EasyOpc.OperationModel;

namespace DocExamples.DataAccess._EasyDAClient
{
    class WriteItem
    {
        public static void Main1()
        {
            // Instantiate the client object.
            var client = new EasyDAClient();

            try
            {
                client.WriteItem("", "OPCLabs.KitServer.2", "Simulation.Register_I4", 
                    12345, DateTime.SpecifyKind(new DateTime(1980, 1, 1), DateTimeKind.Utc), 192);
            }
            catch (OpcException opcException)
            {
                Console.WriteLine($"*** Failure: {opcException.GetBaseException().Message}");
                return;
            }
            Console.WriteLine("Success");
        }
    }
}
# This example shows how to write a value, timestamp and quality into a single item.

# The QuickOPC package is needed. Install it using "pip install opclabs_quickopc".
import opclabs_quickopc

# Import .NET namespaces.
from System import *
from OpcLabs.EasyOpc.DataAccess import *
from OpcLabs.EasyOpc.OperationModel import *


# Instantiate the client object.
client = EasyDAClient()

# Perform the operation
try:
    IEasyDAClientExtension.WriteItem(client, '', 'OPCLabs.KitServer.2', 'Simulation.Register_I4',
                                     12345, DateTime.SpecifyKind(DateTime(1980, 1, 1), DateTimeKind.Utc),
                                     DAQuality(192))
except OpcException as opcException:
    print('*** Failure: ' + opcException.GetBaseException().Message)
    exit()

print('Finished.')
// This example shows how to write a value, timestamp and quality into a single item.

class procedure WriteItem.Main;
var
  Client: OpcLabs_EasyOpcClassic_TLB._EasyDAClient;
begin
  // Instantiate the client object
  Client := CoEasyDAClient.Create;

  try
    Client.WriteItem('', 'OPCLabs.KitServer.2', 'Simulation.Register_I4', 12345, EncodeDate(1980, 1, 1), DAQualities_GoodNonSpecific);
  except
    on E: EOleException do
    begin
      WriteLn(Format('*** Failure: %s', [E.GetBaseException.Message]));
      Exit;
    end;
  end;

end;
Rem This example shows how to write a value, timestamp and quality into a single item.

Option Explicit

Dim Client: Set Client = CreateObject("OpcLabs.EasyOpc.DataAccess.EasyDAClient")
On Error Resume Next
Client.WriteItem "", "OPCLabs.KitServer.2", "Simulation.Register_I4", 12345, DateSerial(1980, 1, 1), 192
If Err.Number <> 0 Then
    WScript.Echo "*** Failure: " & Err.Source & ": " & Err.Description
    WScript.Quit
End If
On Error Goto 0
Requirements

Target Platforms: .NET Framework: Windows 10 (selected versions), Windows 11 (selected versions), Windows Server 2016, Windows Server 2022; .NET: Linux, macOS, Microsoft Windows