OPC Studio User's Guide and Reference
MoveFile(IEasyUAFileTransfer,UAEndpointDescriptor,UANodeDescriptor,UANodeId,UANodeId) Method



OpcLabs.EasyOpcUA Assembly > OpcLabs.EasyOpc.UA.FileTransfer Namespace > IEasyUAFileTransferExtension Class > MoveFile Method : MoveFile(IEasyUAFileTransfer,UAEndpointDescriptor,UANodeDescriptor,UANodeId,UANodeId) Method
The OPC UA file transfer object that will perform the operation.

This is typically the EasyUAFileTransferClient object.

The value of this parameter cannot be null (Nothing in Visual Basic).

Endpoint descriptor. Identifies the OPC-UA server.

Because the OpcLabs.EasyOpc.UA.UAEndpointDescriptor has implicit conversions from System.String and System.Uri, in languages that support implicit conversion operators (such as C# or VB.NET), you can simply use a string (representing the endpoint URL, or a so-called OPC UA endpoint descriptor string), or a System.Uri object, in place of this parameter, and the corresponding endpoint descriptor will be constructed automatically. When the implicit conversion operators are not supported (such as with Python.NET), you can use the OpcLabs.EasyOpc.UA.UAEndpointDescriptor.FromString or OpcLabs.EasyOpc.UA.UAEndpointDescriptor.FromUri static method instead.

Also, because the OpcLabs.EasyOpc.UA.Discovery.UAApplicationElement and OpcLabs.EasyOpc.UA.Discovery.UADiscoveryElement have an implicit conversion to OpcLabs.EasyOpc.UA.UAEndpointDescriptor, in languages that support implicit conversion operators (such as C# or VB.NET), you can simply use a OpcLabs.EasyOpc.UA.Discovery.UAApplicationElement or OpcLabs.EasyOpc.UA.Discovery.UADiscoveryElement (results from OPC UA discovery) in place of this parameter, and the corresponding endpoint descriptor will be constructed automatically. When the implicit conversion operators are not supported (such as with Python.NET), you can convert a (non-null) OpcLabs.EasyOpc.UA.Discovery.UAApplicationElement or OpcLabs.EasyOpc.UA.Discovery.UADiscoveryElement to OpcLabs.EasyOpc.UA.UAEndpointDescriptor using the ToUAEndpointDescriptor or ToUAEndpointDescriptor method instead.

If you are using OPC Wizard (for server development), an implicit conversion from OpcLabs.EasyOpc.UA.EasyUAServerCore can be used in the same way to simply pass the server object in place of this parameter, which will use its OpcLabs.EasyOpc.UA.EasyUAServerCore.EffectiveServerDescriptor property for the connection.

The value of this parameter cannot be null (Nothing in Visual Basic).

Node descriptor of the OPC UA directory.

Because the OpcLabs.EasyOpc.UA.UANodeDescriptor has implicit conversions from OpcLabs.EasyOpc.UA.AddressSpace.UANodeId, OpcLabs.EasyOpc.UA.AddressSpace.UANodeElement, OpcLabs.EasyOpc.UA.Navigation.UABrowsePath and System.String, in languages that support implicit conversion operators (such as C# or VB.NET), you can simply use a OpcLabs.EasyOpc.UA.AddressSpace.UANodeId object (representing the Id of the OPC UA node), a node element object (from OPC UA browsing), OpcLabs.EasyOpc.UA.Navigation.UABrowsePath object (representing OPC UA absolute browse path), or a string (with expanded node Id text) in place of this parameter, and the corresponding node descriptor will be constructed automatically. When the implicit conversion operators are not supported (such as with Python.NET), you can use the OpcLabs.EasyOpc.UA.UANodeDescriptor.FromString, OpcLabs.EasyOpc.UA.UANodeDescriptor.FromUABrowsePath, OpcLabs.EasyOpc.UA.UANodeDescriptor.FromUANodeElement or OpcLabs.EasyOpc.UA.UANodeDescriptor.FromUANodeId static method instead.

If you are using OPC Wizard (for server development), an implicit conversion from OpcLabs.EasyOpc.UA.NodeSpace.UAServerNode can be used in the same way to simply pass the server node in place of this parameter, which will use its OpcLabs.EasyOpc.UA.NodeSpace.UAServerNode.EffectiveNodeDescriptor property for the operation.

The value of this parameter cannot be null (Nothing in Visual Basic).

The node Id of the file to move.

Because the OpcLabs.EasyOpc.UA.AddressSpace.UANodeId has an implicit conversion from System.String, in languages that support implicit conversion operators (such as C# or VB.NET), you can simply use a string (representing the expanded text of the nodeId) in place of this parameter, and the corresponding OPC UA node Id will be constructed automatically. When the implicit conversion operators are not supported (such as with Python.NET), you can use the OpcLabs.EasyOpc.UA.AddressSpace.UANodeId.UANodeId Constructor(String) constructor instead.

The value of this parameter cannot be null (Nothing in Visual Basic).

The node Id of the target directory of the move operation.

Because the OpcLabs.EasyOpc.UA.AddressSpace.UANodeId has an implicit conversion from System.String, in languages that support implicit conversion operators (such as C# or VB.NET), you can simply use a string (representing the expanded text of the nodeId) in place of this parameter, and the corresponding OPC UA node Id will be constructed automatically. When the implicit conversion operators are not supported (such as with Python.NET), you can use the OpcLabs.EasyOpc.UA.AddressSpace.UANodeId.UANodeId Constructor(String) constructor instead.

The value of this parameter cannot be null (Nothing in Visual Basic).

Moves or renames an OPC UA file, specifying the endpoint descriptor, directory node descriptor, existing file node Id, and new directory node Id.
Syntax
'Declaration
 
<ExtensionAttribute()>
<NotNullAttribute()>
Public Overloads Shared Function MoveFile( _
   ByVal fileTransfer As IEasyUAFileTransfer, _
   ByVal endpointDescriptor As UAEndpointDescriptor, _
   ByVal directoryNodeDescriptor As UANodeDescriptor, _
   ByVal existingFileNodeId As UANodeId, _
   ByVal newDirectoryNodeId As UANodeId _
) As UANodeId
'Usage
 
Dim fileTransfer As IEasyUAFileTransfer
Dim endpointDescriptor As UAEndpointDescriptor
Dim directoryNodeDescriptor As UANodeDescriptor
Dim existingFileNodeId As UANodeId
Dim newDirectoryNodeId As UANodeId
Dim value As UANodeId
 
value = IEasyUAFileTransferExtension.MoveFile(fileTransfer, endpointDescriptor, directoryNodeDescriptor, existingFileNodeId, newDirectoryNodeId)

Parameters

fileTransfer
The OPC UA file transfer object that will perform the operation.

This is typically the EasyUAFileTransferClient object.

The value of this parameter cannot be null (Nothing in Visual Basic).

endpointDescriptor
Endpoint descriptor. Identifies the OPC-UA server.

Because the OpcLabs.EasyOpc.UA.UAEndpointDescriptor has implicit conversions from System.String and System.Uri, in languages that support implicit conversion operators (such as C# or VB.NET), you can simply use a string (representing the endpoint URL, or a so-called OPC UA endpoint descriptor string), or a System.Uri object, in place of this parameter, and the corresponding endpoint descriptor will be constructed automatically. When the implicit conversion operators are not supported (such as with Python.NET), you can use the OpcLabs.EasyOpc.UA.UAEndpointDescriptor.FromString or OpcLabs.EasyOpc.UA.UAEndpointDescriptor.FromUri static method instead.

Also, because the OpcLabs.EasyOpc.UA.Discovery.UAApplicationElement and OpcLabs.EasyOpc.UA.Discovery.UADiscoveryElement have an implicit conversion to OpcLabs.EasyOpc.UA.UAEndpointDescriptor, in languages that support implicit conversion operators (such as C# or VB.NET), you can simply use a OpcLabs.EasyOpc.UA.Discovery.UAApplicationElement or OpcLabs.EasyOpc.UA.Discovery.UADiscoveryElement (results from OPC UA discovery) in place of this parameter, and the corresponding endpoint descriptor will be constructed automatically. When the implicit conversion operators are not supported (such as with Python.NET), you can convert a (non-null) OpcLabs.EasyOpc.UA.Discovery.UAApplicationElement or OpcLabs.EasyOpc.UA.Discovery.UADiscoveryElement to OpcLabs.EasyOpc.UA.UAEndpointDescriptor using the ToUAEndpointDescriptor or ToUAEndpointDescriptor method instead.

If you are using OPC Wizard (for server development), an implicit conversion from OpcLabs.EasyOpc.UA.EasyUAServerCore can be used in the same way to simply pass the server object in place of this parameter, which will use its OpcLabs.EasyOpc.UA.EasyUAServerCore.EffectiveServerDescriptor property for the connection.

The value of this parameter cannot be null (Nothing in Visual Basic).

directoryNodeDescriptor
Node descriptor of the OPC UA directory.

Because the OpcLabs.EasyOpc.UA.UANodeDescriptor has implicit conversions from OpcLabs.EasyOpc.UA.AddressSpace.UANodeId, OpcLabs.EasyOpc.UA.AddressSpace.UANodeElement, OpcLabs.EasyOpc.UA.Navigation.UABrowsePath and System.String, in languages that support implicit conversion operators (such as C# or VB.NET), you can simply use a OpcLabs.EasyOpc.UA.AddressSpace.UANodeId object (representing the Id of the OPC UA node), a node element object (from OPC UA browsing), OpcLabs.EasyOpc.UA.Navigation.UABrowsePath object (representing OPC UA absolute browse path), or a string (with expanded node Id text) in place of this parameter, and the corresponding node descriptor will be constructed automatically. When the implicit conversion operators are not supported (such as with Python.NET), you can use the OpcLabs.EasyOpc.UA.UANodeDescriptor.FromString, OpcLabs.EasyOpc.UA.UANodeDescriptor.FromUABrowsePath, OpcLabs.EasyOpc.UA.UANodeDescriptor.FromUANodeElement or OpcLabs.EasyOpc.UA.UANodeDescriptor.FromUANodeId static method instead.

If you are using OPC Wizard (for server development), an implicit conversion from OpcLabs.EasyOpc.UA.NodeSpace.UAServerNode can be used in the same way to simply pass the server node in place of this parameter, which will use its OpcLabs.EasyOpc.UA.NodeSpace.UAServerNode.EffectiveNodeDescriptor property for the operation.

The value of this parameter cannot be null (Nothing in Visual Basic).

existingFileNodeId
The node Id of the file to move.

Because the OpcLabs.EasyOpc.UA.AddressSpace.UANodeId has an implicit conversion from System.String, in languages that support implicit conversion operators (such as C# or VB.NET), you can simply use a string (representing the expanded text of the nodeId) in place of this parameter, and the corresponding OPC UA node Id will be constructed automatically. When the implicit conversion operators are not supported (such as with Python.NET), you can use the OpcLabs.EasyOpc.UA.AddressSpace.UANodeId.UANodeId Constructor(String) constructor instead.

The value of this parameter cannot be null (Nothing in Visual Basic).

newDirectoryNodeId
The node Id of the target directory of the move operation.

Because the OpcLabs.EasyOpc.UA.AddressSpace.UANodeId has an implicit conversion from System.String, in languages that support implicit conversion operators (such as C# or VB.NET), you can simply use a string (representing the expanded text of the nodeId) in place of this parameter, and the corresponding OPC UA node Id will be constructed automatically. When the implicit conversion operators are not supported (such as with Python.NET), you can use the OpcLabs.EasyOpc.UA.AddressSpace.UANodeId.UANodeId Constructor(String) constructor instead.

The value of this parameter cannot be null (Nothing in Visual Basic).

Return Value

Returns the node Id of the moved. The server may return a new node Id for the moved object.

Because there is an implicit conversion from OpcLabs.EasyOpc.UA.AddressSpace.UANodeId to OpcLabs.EasyOpc.UA.UANodeDescriptor, in languages that support implicit conversion operators (such as C# or VB.NET), you can simply use the returned OpcLabs.EasyOpc.UA.AddressSpace.UANodeId in any place where the OpcLabs.EasyOpc.UA.UANodeDescriptor is expected as input, and the corresponding node descriptor will be constructed automatically.

Also, because the OpcLabs.EasyOpc.UA.AddressSpace.UANodeId has an implicit conversion to System.String, and it converts to the expanded text of the node Id (OpcLabs.EasyOpc.UA.AddressSpace.UANodeId.ExpandedText), in languages that support implicit conversion operators (such as C# or VB.NET), you can simply use the returned OpcLabs.EasyOpc.UA.AddressSpace.UANodeId in any place where expanded text of a node Id (a string) is expected as input, and the corresponding expanded text will be taken automatically from the node Id.

This method never returns null (Nothing in Visual Basic).

Exceptions
ExceptionDescription

A null reference (Nothing in Visual Basic) is passed to a method that does not accept it as a valid argument.

This is a usage error, i.e. it will never occur (the exception will not be thrown) in a correctly written program. Your code should not catch this exception.

The OPC UA operation has failed. This operation exception in uniformly used to allow common handling of various kinds of errors. The System.Exception.InnerException always contains information about the actual error cause.

This is an operation error that depends on factors external to your program, and thus cannot be always avoided. Your code must handle it appropriately.

Remarks

This method internally uses the OPC UA File Transfer Method .

The directoryNodeDescriptor must be an existing node in the server, of object type OpcLabs.EasyOpc.UA.AddressSpace.Standard.UAObjectTypeIds.FileDirectoryType.

The existingFileNodeId must be an existing node in the server, of object type OpcLabs.EasyOpc.UA.AddressSpace.Standard.UAObjectTypeIds.FileType.

Recommendation: Whenever possible, do not use this method directly, and use a higher-level abstraction instead. You can obtain a writable file provider (using GetWritableFileProvider), and make use of its methods, and methods available on the writable directory contents (obtained using OpcLabs.BaseLib.Extensions.FileProviders.IWritableDirectory.GetWritableDirectoryContents) or writable file info (obtained using OpcLabs.BaseLib.Extensions.FileProviders.IWritableDirectory.GetWritableFileInfo).

This is an extension method (info: C#, VB.NET). In languages that have support for extensions methods (such as C# and VB.NET), you can use the extension method as if it were a regular method on the object that is its first parameter. In other languages (such as with Python.NET), you will call the extension as a static method, and pass it the object on which it acts as its first parameter.

Requirements

Target Platforms: .NET Framework: Windows 10 (selected versions), Windows 11 (selected versions), Windows Server 2016, Windows Server 2022; .NET: Linux, macOS, Microsoft Windows

See Also