LinkRetrialDelay Property (EasyAELinkParameters)



OpcLabs.EasyOpcClassicCore Assembly > OpcLabs.EasyOpc.AlarmsAndEvents.Engine Namespace > EasyAELinkParameters Class : LinkRetrialDelay Property
Link retrial delay. Number of milliseconds. If a specific OPC link is found to be not operational, further attempts to use it will not be made until the link retrial delay elapses. One of typical reasons for entering the link retrial period is using an unknown OPC area or source name, which can later become correct when the OPC server configuration is updated.
Syntax
'Declaration
 
<DataMemberAttribute()>
<ValueLimitsAttribute(0, 2147483647)>
Public Property LinkRetrialDelay As Integer
'Usage
 
Dim instance As EasyAELinkParameters
Dim value As Integer
 
instance.LinkRetrialDelay = value
 
value = instance.LinkRetrialDelay
[DataMember()]
[ValueLimits(0, 2147483647)]
public int LinkRetrialDelay {get; set;}
[DataMember()]
[ValueLimits(0, 2147483647)]
public:
property int LinkRetrialDelay {
   int get();
   void set (    int value);
}

Property Value

The default value of this property is 60000.

Exceptions
ExceptionDescription

The value of an argument is outside the allowable range of values as defined by the invoked method.

This is a usage error, i.e. it will never occur (the exception will not be thrown) in a correctly written program. Your code should not catch this exception.

Remarks

The value must be greater than or equal to zero.

Requirements

Target Platforms: .NET Framework: Windows 10 (selected versions), Windows 11 (selected versions), Windows Server 2016, Windows Server 2022; .NET: Linux, macOS, Microsoft Windows