Waits until the specified attribute becomes "good". Specify endpoint descriptor and node descriptor.
Syntax
Parameters
- client
- The client object that will perform the operation.
This is typically the OpcLabs.EasyOpc.UA.EasyUAClient object.
The value of this parameter cannot be null
(Nothing
in Visual Basic).
- endpointDescriptor
- The endpoint descriptor.
Because the OpcLabs.EasyOpc.UA.UAEndpointDescriptor has implicit conversions from System.String and System.Uri, in languages that support implicit conversion operators (such as C# or VB.NET), you can simply use a string (representing the endpoint URL, or a so-called OPC UA endpoint descriptor string), or a System.Uri object, in place of this parameter, and the corresponding endpoint descriptor will be constructed automatically. When the implicit conversion operators are not supported (such as with Python.NET), you can use the OpcLabs.EasyOpc.UA.UAEndpointDescriptor.FromString or OpcLabs.EasyOpc.UA.UAEndpointDescriptor.FromUri static method instead.
Also, because the OpcLabs.EasyOpc.UA.Discovery.UAApplicationElement and OpcLabs.EasyOpc.UA.Discovery.UADiscoveryElement have an implicit conversion to OpcLabs.EasyOpc.UA.UAEndpointDescriptor, in languages that support implicit conversion operators (such as C# or VB.NET), you can simply use a OpcLabs.EasyOpc.UA.Discovery.UAApplicationElement or OpcLabs.EasyOpc.UA.Discovery.UADiscoveryElement (results from OPC UA discovery) in place of this parameter, and the corresponding endpoint descriptor will be constructed automatically. When the implicit conversion operators are not supported (such as with Python.NET), you can convert a (non-null) OpcLabs.EasyOpc.UA.Discovery.UAApplicationElement or OpcLabs.EasyOpc.UA.Discovery.UADiscoveryElement to OpcLabs.EasyOpc.UA.UAEndpointDescriptor using the ToUAEndpointDescriptor or ToUAEndpointDescriptor method instead.
If you are using OPC Wizard (for server development), an implicit conversion from OpcLabs.EasyOpc.UA.EasyUAServerCore can be used in the same way to simply pass the server object in place of this parameter, which will use its OpcLabs.EasyOpc.UA.EasyUAServerCore.EffectiveServerDescriptor property for the connection.
The value of this parameter cannot be null
(Nothing
in Visual Basic).
- nodeDescriptor
- Node descriptor. Identifies the node in OPC server's address space.
Because the OpcLabs.EasyOpc.UA.UANodeDescriptor has implicit conversions from OpcLabs.EasyOpc.UA.AddressSpace.UANodeId, OpcLabs.EasyOpc.UA.AddressSpace.UANodeElement, OpcLabs.EasyOpc.UA.Navigation.UABrowsePath and System.String, in languages that support implicit conversion operators (such as C# or VB.NET), you can simply use a OpcLabs.EasyOpc.UA.AddressSpace.UANodeId object (representing the Id of the OPC UA node), a node element object (from OPC UA browsing), OpcLabs.EasyOpc.UA.Navigation.UABrowsePath object (representing OPC UA absolute browse path), or a string (with expanded node Id text) in place of this parameter, and the corresponding node descriptor will be constructed automatically. When the implicit conversion operators are not supported (such as with Python.NET), you can use the OpcLabs.EasyOpc.UA.UANodeDescriptor.FromString, OpcLabs.EasyOpc.UA.UANodeDescriptor.FromUABrowsePath, OpcLabs.EasyOpc.UA.UANodeDescriptor.FromUANodeElement or OpcLabs.EasyOpc.UA.UANodeDescriptor.FromUANodeId static method instead.
If you are using OPC Wizard (for server development), an implicit conversion from OpcLabs.EasyOpc.UA.NodeSpace.UAServerNode can be used in the same way to simply pass the server node in place of this parameter, which will use its OpcLabs.EasyOpc.UA.NodeSpace.UAServerNode.EffectiveNodeDescriptor property for the operation.
The value of this parameter cannot be null
(Nothing
in Visual Basic).
Return Value
If successful, the function returns the actual value of node&attribute requested.
This method can return null
(Nothing
in Visual Basic).
Exceptions
Exception | Description |
System.ArgumentNullException |
A null reference (Nothing in Visual Basic) is passed to a method that does not accept it as a valid argument.
This is a usage error, i.e. it will never occur (the exception will not be thrown) in a correctly written program. Your code should not catch this exception. |
OpcLabs.EasyOpc.UA.OperationModel.UAException |
The OPC UA operation has failed. This operation exception in uniformly used to allow
common handling of various kinds of errors. The System.Exception.InnerException always contains
information about the actual error cause.
This is an operation error that depends on factors external to your program, and thus cannot be always avoided. Your code must handle it appropriately. |
Example
// This example shows how to wait on an item until a value with "good" status severity becomes available.
//
// Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .
// OPC client and subscriber examples in C# on GitHub: https://github.com/OPCLabs/Examples-QuickOPC-CSharp .
// Missing some example? Ask us for it on our Online Forums, https://www.opclabs.com/forum/index ! You do not have to own
// a commercial license in order to use Online Forums, and we reply to every post.
using System;
using OpcLabs.EasyOpc.UA;
using OpcLabs.EasyOpc.UA.Extensions;
using OpcLabs.EasyOpc.UA.OperationModel;
namespace UADocExamples._EasyUAClientExtension
{
class WaitForValue
{
public static void Main1()
{
UAEndpointDescriptor endpointDescriptor =
"opc.tcp://opcua.demo-this.com:51210/UA/SampleServer";
// or "http://opcua.demo-this.com:51211/UA/SampleServer" (currently not supported)
// or "https://opcua.demo-this.com:51212/UA/SampleServer/"
// Instantiate the client object
var client = new EasyUAClient();
Console.WriteLine("Waiting until an item value with \"good\" status severity becomes available...");
object value;
try
{
value = client.WaitForValue(endpointDescriptor, "nsu=http://test.org/UA/Data/ ;i=10221",
monitoringParameters: 100, // this is the sampling rate
millisecondsTimeout: 60*1000);
}
catch (UAException uaException)
{
Console.WriteLine("*** Failure: {0}", uaException.GetBaseException().Message);
return;
}
// Display the obtained value.
Console.WriteLine("value: {0}", value);
}
}
}
' This example shows how to wait on an item until a value with "good" status severity becomes available.
'
' Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .
' OPC client and subscriber examples in VB.NET on GitHub: https://github.com/OPCLabs/Examples-QuickOPC-VBNET .
' Missing some example? Ask us for it on our Online Forums, https://www.opclabs.com/forum/index ! You do not have to own
' a commercial license in order to use Online Forums, and we reply to every post.
Imports Opc.Ua
Imports OpcLabs.EasyOpc.UA
Imports OpcLabs.EasyOpc.UA.Extensions
Imports OpcLabs.EasyOpc.UA.OperationModel
Namespace _EasyUAClientExtension
Friend Class WaitForValue
Public Shared Sub Main1()
' Define which server we will work with.
Dim endpointDescriptor As UAEndpointDescriptor =
"opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"
' or "http://opcua.demo-this.com:51211/UA/SampleServer" (currently not supported)
' or "https://opcua.demo-this.com:51212/UA/SampleServer/"
' Instantiate the client object
Dim client = New EasyUAClient()
Console.WriteLine("Waiting until an item value with ""good"" status severity becomes available...")
Dim value As Object
Try
value = client.WaitForValue(endpointDescriptor, "nsu=http://test.org/UA/Data/ ;i=10221",
monitoringParameters:=100, ' this is the sampling rate
millisecondsTimeout:=60 * 1000)
Catch uaException As UAException
Console.WriteLine("*** Failure: {0}", uaException.GetBaseException.Message)
Exit Sub
End Try
' Display the obtained value.
Console.WriteLine("value: {0}", value)
End Sub
End Class
End Namespace
# This example shows how to wait on an item until a value with "good" status severity becomes available.
#
# Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .
# OPC client and subscriber examples in Python on GitHub: https://github.com/OPCLabs/Examples-QuickOPC-Python .
# Missing some example? Ask us for it on our Online Forums, https://www.opclabs.com/forum/index ! You do not have to own
# a commercial license in order to use Online Forums, and we reply to every post.
# The QuickOPC package is needed. Install it using "pip install opclabs_quickopc".
import opclabs_quickopc
# Import .NET namespaces.
from OpcLabs.EasyOpc.UA import *
from OpcLabs.EasyOpc.UA.Extensions import *
from OpcLabs.EasyOpc.UA.OperationModel import *
endpointDescriptor = UAEndpointDescriptor('opc.tcp://opcua.demo-this.com:51210/UA/SampleServer')
# or 'http://opcua.demo-this.com:51211/UA/SampleServer' (currently not supported)
# or 'https://opcua.demo-this.com:51212/UA/SampleServer/'
# Instantiate the client object.
client = EasyUAClient()
print('Waiting until an item value with "good" status severity becomes available...')
try:
value = IEasyUAClientExtension2.WaitForValue(client,
endpointDescriptor,
UANodeDescriptor('nsu=http://test.org/UA/Data/ ;i=10221'),
UAMonitoringParameters(100), # this is the sampling rate
60*1000) # millisecondsTimeout
except UAException as uaException:
print('*** Failure: ' + uaException.GetBaseException().Message)
exit()
# Display the obtained value.
print('value: ', value, sep='')
print()
print('Finished.')
Requirements
Target Platforms: .NET Framework: Windows 10 (selected versions), Windows 11 (selected versions), Windows Server 2016, Windows Server 2022; .NET: Linux, macOS, Microsoft Windows
See Also