Property Value
Valid values of this property are in the range from 1
to 2147483647 (Int32.MaxValue)
.
Unit of measurement is ms
.
The default value of this property is 120000
.
Valid values of this property are in the range from 1
to 2147483647 (Int32.MaxValue)
.
Unit of measurement is ms
.
The default value of this property is 120000
.
Exception | Description |
---|---|
System.ArgumentOutOfRangeException | The value of an argument is outside the allowable range of values as defined by the invoked method. This is a usage error, i.e. it will never occur (the exception will not be thrown) in a correctly written program. Your code should not catch this exception. |
This parameter is not interpreted by the component; it is simply passed down to the OPC UA Stack for processing. It determines how long the stack waits for a response after sending a request.
This parameter controls the operation timeout for the majority of OPC UA operations. Some operations (such as endpoint selection, or closing the session) may use a different value for their operation timeout, controlled by a different parameter.
In order to obtain or modify this parameter, in the default state (when OpcLabs.EasyOpc.UA.EasyUAClientCore.Isolated equals to false
), access UAClientAdaptableParameters.SessionParameters property of static OpcLabs.EasyOpc.UA.EasyUAClientCore.AdaptableParameters. If you have set OpcLabs.EasyOpc.UA.EasyUAClientCore.Isolated to true
, you need to access UAClientAdaptableParameters.SessionParameters property of OpcLabs.EasyOpc.UA.EasyUAClientCore.IsolatedParameters.
The getter method of this property is pure, i.e. it does not have observable side effects.