OPC Studio User's Guide and Reference
HasFileSystem(IEasyUAFileTransfer,UAEndpointDescriptor,UANodeDescriptor) Method



OpcLabs.EasyOpcUA Assembly > OpcLabs.EasyOpc.UA.FileTransfer Namespace > IEasyUAFileTransferExtension Class > HasFileSystem Method : HasFileSystem(IEasyUAFileTransfer,UAEndpointDescriptor,UANodeDescriptor) Method
The OPC UA file transfer object that will perform the operation.

This is typically the EasyUAFileTransferClient object.

The value of this parameter cannot be null (Nothing in Visual Basic).

Endpoint descriptor. Identifies the OPC-UA server.

Because the OpcLabs.EasyOpc.UA.UAEndpointDescriptor has implicit conversions from System.String and System.Uri, in languages that support implicit conversion operators (such as C# or VB.NET), you can simply use a string (representing the endpoint URL, or a so-called OPC UA endpoint descriptor string), or a System.Uri object, in place of this parameter, and the corresponding endpoint descriptor will be constructed automatically. When the implicit conversion operators are not supported (such as with Python.NET), you can use the OpcLabs.EasyOpc.UA.UAEndpointDescriptor.FromString or OpcLabs.EasyOpc.UA.UAEndpointDescriptor.FromUri static method instead.

Also, because the OpcLabs.EasyOpc.UA.Discovery.UAApplicationElement and OpcLabs.EasyOpc.UA.Discovery.UADiscoveryElement have an implicit conversion to OpcLabs.EasyOpc.UA.UAEndpointDescriptor, in languages that support implicit conversion operators (such as C# or VB.NET), you can simply use a OpcLabs.EasyOpc.UA.Discovery.UAApplicationElement or OpcLabs.EasyOpc.UA.Discovery.UADiscoveryElement (results from OPC UA discovery) in place of this parameter, and the corresponding endpoint descriptor will be constructed automatically. When the implicit conversion operators are not supported (such as with Python.NET), you can convert a (non-null) OpcLabs.EasyOpc.UA.Discovery.UAApplicationElement or OpcLabs.EasyOpc.UA.Discovery.UADiscoveryElement to OpcLabs.EasyOpc.UA.UAEndpointDescriptor using the ToUAEndpointDescriptor or ToUAEndpointDescriptor method instead.

If you are using OPC Wizard (for server development), an implicit conversion from OpcLabs.EasyOpc.UA.EasyUAServerCore can be used in the same way to simply pass the server object in place of this parameter, which will use its OpcLabs.EasyOpc.UA.EasyUAServerCore.EffectiveServerDescriptor property for the connection.

The value of this parameter cannot be null (Nothing in Visual Basic).

A node descriptor of the object whose file system's presence should be tested.

Because the OpcLabs.EasyOpc.UA.UANodeDescriptor has implicit conversions from OpcLabs.EasyOpc.UA.AddressSpace.UANodeId, OpcLabs.EasyOpc.UA.AddressSpace.UANodeElement, OpcLabs.EasyOpc.UA.Navigation.UABrowsePath and System.String, in languages that support implicit conversion operators (such as C# or VB.NET), you can simply use a OpcLabs.EasyOpc.UA.AddressSpace.UANodeId object (representing the Id of the OPC UA node), a node element object (from OPC UA browsing), OpcLabs.EasyOpc.UA.Navigation.UABrowsePath object (representing OPC UA absolute browse path), or a string (with expanded node Id text) in place of this parameter, and the corresponding node descriptor will be constructed automatically. When the implicit conversion operators are not supported (such as with Python.NET), you can use the OpcLabs.EasyOpc.UA.UANodeDescriptor.FromString, OpcLabs.EasyOpc.UA.UANodeDescriptor.FromUABrowsePath, OpcLabs.EasyOpc.UA.UANodeDescriptor.FromUANodeElement or OpcLabs.EasyOpc.UA.UANodeDescriptor.FromUANodeId static method instead.

If you are using OPC Wizard (for server development), an implicit conversion from OpcLabs.EasyOpc.UA.NodeSpace.UAServerNode can be used in the same way to simply pass the server node in place of this parameter, which will use its OpcLabs.EasyOpc.UA.NodeSpace.UAServerNode.EffectiveNodeDescriptor property for the operation.

The value of this parameter cannot be null (Nothing in Visual Basic).

Determines whether the specified OPC UA object contains a file system object component, specifying the endpoint descriptor, and object node descriptor.
Syntax
'Declaration
 
<ExtensionAttribute()>
Public Overloads Shared Function HasFileSystem( _
   ByVal fileTransfer As IEasyUAFileTransfer, _
   ByVal endpointDescriptor As UAEndpointDescriptor, _
   ByVal objectNodeDescriptor As UANodeDescriptor _
) As Boolean
'Usage
 
Dim fileTransfer As IEasyUAFileTransfer
Dim endpointDescriptor As UAEndpointDescriptor
Dim objectNodeDescriptor As UANodeDescriptor
Dim value As Boolean
 
value = IEasyUAFileTransferExtension.HasFileSystem(fileTransfer, endpointDescriptor, objectNodeDescriptor)

Parameters

fileTransfer
The OPC UA file transfer object that will perform the operation.

This is typically the EasyUAFileTransferClient object.

The value of this parameter cannot be null (Nothing in Visual Basic).

endpointDescriptor
Endpoint descriptor. Identifies the OPC-UA server.

Because the OpcLabs.EasyOpc.UA.UAEndpointDescriptor has implicit conversions from System.String and System.Uri, in languages that support implicit conversion operators (such as C# or VB.NET), you can simply use a string (representing the endpoint URL, or a so-called OPC UA endpoint descriptor string), or a System.Uri object, in place of this parameter, and the corresponding endpoint descriptor will be constructed automatically. When the implicit conversion operators are not supported (such as with Python.NET), you can use the OpcLabs.EasyOpc.UA.UAEndpointDescriptor.FromString or OpcLabs.EasyOpc.UA.UAEndpointDescriptor.FromUri static method instead.

Also, because the OpcLabs.EasyOpc.UA.Discovery.UAApplicationElement and OpcLabs.EasyOpc.UA.Discovery.UADiscoveryElement have an implicit conversion to OpcLabs.EasyOpc.UA.UAEndpointDescriptor, in languages that support implicit conversion operators (such as C# or VB.NET), you can simply use a OpcLabs.EasyOpc.UA.Discovery.UAApplicationElement or OpcLabs.EasyOpc.UA.Discovery.UADiscoveryElement (results from OPC UA discovery) in place of this parameter, and the corresponding endpoint descriptor will be constructed automatically. When the implicit conversion operators are not supported (such as with Python.NET), you can convert a (non-null) OpcLabs.EasyOpc.UA.Discovery.UAApplicationElement or OpcLabs.EasyOpc.UA.Discovery.UADiscoveryElement to OpcLabs.EasyOpc.UA.UAEndpointDescriptor using the ToUAEndpointDescriptor or ToUAEndpointDescriptor method instead.

If you are using OPC Wizard (for server development), an implicit conversion from OpcLabs.EasyOpc.UA.EasyUAServerCore can be used in the same way to simply pass the server object in place of this parameter, which will use its OpcLabs.EasyOpc.UA.EasyUAServerCore.EffectiveServerDescriptor property for the connection.

The value of this parameter cannot be null (Nothing in Visual Basic).

objectNodeDescriptor
A node descriptor of the object whose file system's presence should be tested.

Because the OpcLabs.EasyOpc.UA.UANodeDescriptor has implicit conversions from OpcLabs.EasyOpc.UA.AddressSpace.UANodeId, OpcLabs.EasyOpc.UA.AddressSpace.UANodeElement, OpcLabs.EasyOpc.UA.Navigation.UABrowsePath and System.String, in languages that support implicit conversion operators (such as C# or VB.NET), you can simply use a OpcLabs.EasyOpc.UA.AddressSpace.UANodeId object (representing the Id of the OPC UA node), a node element object (from OPC UA browsing), OpcLabs.EasyOpc.UA.Navigation.UABrowsePath object (representing OPC UA absolute browse path), or a string (with expanded node Id text) in place of this parameter, and the corresponding node descriptor will be constructed automatically. When the implicit conversion operators are not supported (such as with Python.NET), you can use the OpcLabs.EasyOpc.UA.UANodeDescriptor.FromString, OpcLabs.EasyOpc.UA.UANodeDescriptor.FromUABrowsePath, OpcLabs.EasyOpc.UA.UANodeDescriptor.FromUANodeElement or OpcLabs.EasyOpc.UA.UANodeDescriptor.FromUANodeId static method instead.

If you are using OPC Wizard (for server development), an implicit conversion from OpcLabs.EasyOpc.UA.NodeSpace.UAServerNode can be used in the same way to simply pass the server node in place of this parameter, which will use its OpcLabs.EasyOpc.UA.NodeSpace.UAServerNode.EffectiveNodeDescriptor property for the operation.

The value of this parameter cannot be null (Nothing in Visual Basic).

Return Value

Returns true is there is a file system object component under the objectNodeDescriptor node. Returns false otherwise.
Exceptions
ExceptionDescription

A null reference (Nothing in Visual Basic) is passed to a method that does not accept it as a valid argument.

This is a usage error, i.e. it will never occur (the exception will not be thrown) in a correctly written program. Your code should not catch this exception.

The OPC UA operation has failed. This operation exception in uniformly used to allow common handling of various kinds of errors. The System.Exception.InnerException always contains information about the actual error cause.

This is an operation error that depends on factors external to your program, and thus cannot be always avoided. Your code must handle it appropriately.

Remarks

This is an extension method (info: C#, VB.NET). In languages that have support for extensions methods (such as C# and VB.NET), you can use the extension method as if it were a regular method on the object that is its first parameter. In other languages (such as with Python.NET), you will call the extension as a static method, and pass it the object on which it acts as its first parameter.

Requirements

Target Platforms: .NET Framework: Windows 10 (selected versions), Windows 11 (selected versions), Windows Server 2016, Windows Server 2022; .NET: Linux, macOS, Microsoft Windows

See Also

Reference

IEasyUAFileTransferExtension Class
IEasyUAFileTransferExtension Members
Overload List
OpcLabs.EasyOpc.UA.FileTransfer.IEasyUAFileTransferExtension.FindFileSystem(OpcLabs.EasyOpc.UA.FileTransfer.IEasyUAFileTransfer,OpcLabs.EasyOpc.UA.UAEndpointDescriptor)
GetFileSystem(IEasyUAFileTransfer,UAEndpointDescriptor) Method