OPC Studio User's Guide and Reference
LogEntry Method (DEasyUAClientManagementEvents)
Example 



OpcLabs.EasyOpcUA Assembly > OpcLabs.EasyOpc.UA.ComTypes Namespace > DEasyUAClientManagementEvents Interface : LogEntry Method

The value of this parameter cannot be null (Nothing in Visual Basic).

The value of this parameter cannot be null (Nothing in Visual Basic).

Raised for loggable entries originating in the OPC-UA client engine and the EasyUAClient component.
Syntax
'Declaration
 
<DispIdAttribute(1001)>
Sub LogEntry( _
   ByVal sender0 As Object, _
   ByVal eventArgs As LogEntryEventArgs _
) 
'Usage
 
Dim instance As DEasyUAClientManagementEvents
Dim sender0 As Object
Dim eventArgs As LogEntryEventArgs
 
instance.LogEntry(sender0, eventArgs)
[DispId(1001)]
void LogEntry( 
   object sender0,
   LogEntryEventArgs eventArgs
)
[DispId(1001)]
void LogEntry( 
   Object^ sender0,
   LogEntryEventArgs^ eventArgs
) 

Parameters

sender0

The value of this parameter cannot be null (Nothing in Visual Basic).

eventArgs

The value of this parameter cannot be null (Nothing in Visual Basic).

Remarks

This member or type is for use from COM. It is not meant to be used from .NET or Python. Refer to the corresponding .NET member or type instead, if you are developing in .NET or Python.

Example

COM

// This example demonstrates the loggable entries originating in the OPC-UA client engine and the EasyUAClient component.
//
// Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .
// Missing some example? Ask us for it on our Online Forums, https://www.opclabs.com/forum/index ! You do not have to own
// a commercial license in order to use Online Forums, and we reply to every post.

#include "stdafx.h"    // Includes "QuickOpc.h", and other commonly used files
#include <atlcom.h>
#include "LogEntry.h"

namespace _EasyUAClientManagement
{
    // CEasyUAClientManagementEvents

    class CEasyUAClientManagementEvents : public IDispEventImpl<1, CEasyUAClientManagementEvents>
    {
    public:
    BEGIN_SINK_MAP(CEasyUAClientManagementEvents)
        // Event handlers must have the __stdcall calling convention
        SINK_ENTRY(1, 1 /*DISPID_EASYUACLIENTManagementEVENTS_LOGENTRY*/, &CEasyUAClientManagementEvents::LogEntry)
    END_SINK_MAP()

    public:
        // Event handler for the LogEntry event. It simply prints out the event.
        STDMETHOD(LogEntry)(VARIANT varSender, _LogEntryEventArgs* pEventArgs)
        {
            _tprintf(_T("%s\n"), (LPCTSTR)CW2CT(pEventArgs->ToString));
            return S_OK;
        }
    };



    void LogEntry::Main()
    {
        // Initialize the COM library
        CoInitializeEx(NULL, COINIT_MULTITHREADED);
        {
            // The management object allows access to static behavior - here, the shared LogEntry event.
            _EasyUAClientManagementPtr ClientManagementPtr(__uuidof(EasyUAClientManagement));

            // Hook events
            CEasyUAClientManagementEvents* pClientManagementEvents = new CEasyUAClientManagementEvents();
            AtlGetObjectSourceInterface(ClientManagementPtr, &pClientManagementEvents->m_libid, 
                &pClientManagementEvents->m_iid, 
                &pClientManagementEvents->m_wMajorVerNum, &pClientManagementEvents->m_wMinorVerNum);
            pClientManagementEvents->m_iid = _uuidof(DEasyUAClientManagementEvents);
            pClientManagementEvents->DispEventAdvise(ClientManagementPtr, &pClientManagementEvents->m_iid);

            // Do something - invoke an OPC read, to trigger some loggable entries.
            _EasyUAClientPtr ClientPtr(__uuidof(EasyUAClient));
            ClientPtr->ReadValue(
                //L"http://opcua.demo-this.com:51211/UA/SampleServer", 
                L"opc.tcp://opcua.demo-this.com:51210/UA/SampleServer",
                L"nsu=http://test.org/UA/Data/ ;i=10853");

            _tprintf(_T("Processing log entry events for 1 minute...\n"));
            Sleep(60*1000);

            // Unhook events
            pClientManagementEvents->DispEventUnadvise(ClientManagementPtr, &pClientManagementEvents->m_iid);
        }
         // Release all interface pointers BEFORE calling CoUninitialize()
        CoUninitialize();
    }
}
// This example demonstrates the loggable entries originating in the OPC-UA
// client engine and the EasyUAClient component.
//
// Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .
// Missing some example? Ask us for it on our Online Forums, https://www.opclabs.com/forum/index ! You do not have to own
// a commercial license in order to use Online Forums, and we reply to every post.

type
  TClientManagementEventHandlers = class
    procedure OnLogEntry(
      Sender: TObject;
      sender0: OleVariant;
      eventArgs: _LogEntryEventArgs);
  end;

// Event handler for the LogEntry event. It simply prints out the event.
procedure TClientManagementEventHandlers.OnLogEntry(
  Sender: TObject;
  sender0: OleVariant;
  eventArgs: _LogEntryEventArgs);
begin
    WriteLn(eventArgs.ToString);
end;

class procedure LogEntry.Main;
var
  Client: EasyUAClient;
  EvsClientManagement: TEvsEasyUAClientManagement;
  ClientManagement: EasyUAClientManagement;
  ClientManagementEventHandlers: TClientManagementEventHandlers;
  Value: OleVariant;
begin
  // The Management object allows access to static behavior - here, the
  // shared LogEntry event.
  EvsClientManagement := TEvsEasyUAClientManagement.Create(nil);
  ClientManagement := EvsClientManagement.ComServer;
  ClientManagementEventHandlers := TClientManagementEventHandlers.Create;
  EvsClientManagement.OnLogEntry := @ClientManagementEventHandlers.OnLogEntry;

  // Do something - invoke an OPC read, to trigger some loggable entries.
  Client := CoEasyUAClient.Create;
  Value := Client.ReadValue(
    //'http://opcua.demo-this.com:51211/UA/SampleServer',
    'opc.tcp://opcua.demo-this.com:51210/UA/SampleServer',
    'nsu=http://test.org/UA/Data/ ;i=10853');

  WriteLn('Processing log entry events for 1 minute...');
  PumpSleep(60*1000);
end;
// This example demonstrates the loggable entries originating in the OPC-UA
// client engine and the EasyUAClient component.
//
// Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .
// OPC client and subscriber examples in Object Pascal (Delphi) on GitHub: https://github.com/OPCLabs/Examples-QuickOPC-OP .
// Missing some example? Ask us for it on our Online Forums, https://www.opclabs.com/forum/index ! You do not have to own
// a commercial license in order to use Online Forums, and we reply to every post.

type
  TClientManagementEventHandlers130 = class
    procedure OnLogEntry(
      ASender: TObject;
      sender: OleVariant;
      const eventArgs: _LogEntryEventArgs);
  end;

// Event handler for the LogEntry event. It simply prints out the event.
procedure TClientManagementEventHandlers130.OnLogEntry(
  ASender: TObject;
  sender: OleVariant;
  const eventArgs: _LogEntryEventArgs);
begin
    WriteLn(eventArgs.ToString);
end;

class procedure LogEntry.Main;
var
  Client: OpcLabs_EasyOpcUA_TLB._EasyUAClient;
  ClientManagement: TEasyUAClientManagement;
  ClientManagementEventHandlers: TClientManagementEventHandlers130;
  Value: OleVariant;
begin
  // The management object allows access to static behavior - here, the
  // shared LogEntry event.
  ClientManagement := TEasyUAClientManagement.Create(nil);
  ClientManagementEventHandlers := TClientManagementEventHandlers130.Create;
  ClientManagement.OnLogEntry := ClientManagementEventHandlers.OnLogEntry;
  ClientManagement.Connect;

  // Do something - invoke an OPC read, to trigger some loggable entries.
  Client := CoEasyUAClient.Create;
  try
    Value := Client.ReadValue(
      //'http://opcua.demo-this.com:51211/UA/SampleServer',
      //'https://opcua.demo-this.com:51212/UA/SampleServer/',
      'opc.tcp://opcua.demo-this.com:51210/UA/SampleServer',
      'nsu=http://test.org/UA/Data/ ;i=10853');
  except
    on E: EOleException do
    begin
      WriteLn(Format('*** Failure: %s', [E.GetBaseException.Message]));
      //Exit;
    end;
  end;

  WriteLn('Processing log entry events for 1 minute...');
  PumpSleep(60*1000);

  WriteLn('Finished.');
  FreeAndNil(ClientManagement);
  FreeAndNil(ClientManagementEventHandlers);
end;
// This example demonstrates the loggable entries originating in the OPC-UA client engine and the EasyUAClient component.
//
// Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .
// OPC client and subscriber examples in PHP on GitHub: https://github.com/OPCLabs/Examples-QuickOPC-PHP .
// Missing some example? Ask us for it on our Online Forums, https://www.opclabs.com/forum/index ! You do not have to own
// a commercial license in order to use Online Forums, and we reply to every post.

class ClientManagementEvents {
    // Event handler for the LogEntry event. It simply prints out the event.
    function LogEntry($Sender, $E)
    {
    printf("%s\n", $E);
    }
}



// The management object allows access to static behavior - here, the shared LogEntry event.
$ClientManagement = new COM("OpcLabs.EasyOpc.UA.EasyUAClientManagement");
$ClientManagementEvents = new ClientManagementEvents();
com_event_sink($ClientManagement, $ClientManagementEvents, "DEasyUAClientManagementEvents");

// Do something - invoke an OPC read, to trigger some loggable entries.
$Client = new COM("OpcLabs.EasyOpc.UA.EasyUAClient");
try
{
    $value = $Client->ReadValue(
        //"http://opcua.demo-this.com:51211/UA/SampleServer", 
        "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer", 
        "nsu=http://test.org/UA/Data/ ;i=10853");
}
catch (com_exception $e)
{
    printf("*** Failure: %s\n", $e->getMessage());
    Exit();
}


printf("Processing log entry events for 1 minute...");
$startTime = time(); do { com_message_pump(1000); } while (time() < $startTime + 60);
REM This example demonstrates the loggable entries originating in the OPC-UA client engine and the EasyUAClient component.
REM
REM Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .
REM OPC client and subscriber examples in Visual Basic on GitHub: https://github.com/OPCLabs/Examples-QuickOPC-VB .
REM Missing some example? Ask us for it on our Online Forums, https://www.opclabs.com/forum/index ! You do not have to own
REM a commercial license in order to use Online Forums, and we reply to every post.

' The management object allows access to static behavior - here, the shared LogEntry event.
'Public WithEvents ClientManagement1 As EasyUAClientManagement

Private Sub LogEntry_Main_Command_Click()
    OutputText = ""
    
    Set ClientManagement1 = New EasyUAClientManagement
    
    ' Do something - invoke an OPC read, to trigger some loggable entries.
    Dim client As New EasyUAClient
    On Error Resume Next
    Dim value As Variant
    value = client.ReadValue("opc.tcp://opcua.demo-this.com:51210/UA/SampleServer", "nsu=http://test.org/UA/Data/ ;i=10853")
    If Err.Number <> 0 Then
        OutputText = OutputText & "*** Failure: " & Err.Source & ": " & Err.Description & vbCrLf
        Exit Sub
    End If
    On Error GoTo 0

    OutputText = OutputText & "Processing log entry events for 1 minute..." & vbCrLf
    Pause 60000
    
    Set ClientManagement1 = Nothing
    OutputText = OutputText & "Finished..." & vbCrLf
End Sub

' Event handler for the LogEntry event. It simply prints out the event.
Private Sub ClientManagement1_LogEntry(ByVal sender As Variant, ByVal eventArgs As OpcLabs_BaseLib.LogEntryEventArgs)
    OutputText = OutputText & eventArgs & vbCrLf
End Sub
Rem This example demonstrates the loggable entries originating in the OPC-UA client engine and the EasyUAClient component.
Rem
Rem Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .
Rem OPC client and subscriber examples in VBScript on GitHub: https://github.com/OPCLabs/Examples-QuickOPC-VBScript .
Rem Missing some example? Ask us for it on our Online Forums, https://www.opclabs.com/forum/index ! You do not have to own
Rem a commercial license in order to use Online Forums, and we reply to every post.

Option Explicit

' The management object allows access to static behavior - here, the shared LogEntry event.
Dim ClientManagement: Set ClientManagement = CreateObject("OpcLabs.EasyOpc.UA.EasyUAClientManagement")
WScript.ConnectObject ClientManagement, "ClientManagement_"

' Do something - invoke an OPC read, to trigger some loggable entries.
Dim Client: Set Client = CreateObject("OpcLabs.EasyOpc.UA.EasyUAClient")
On Error Resume Next
Dim value: value = Client.ReadValue("opc.tcp://opcua.demo-this.com:51210/UA/SampleServer", "nsu=http://test.org/UA/Data/ ;i=10853")
If Err.Number <> 0 Then
    WScript.Echo "*** Failure: " & Err.Source & ": " & Err.Description
    WScript.Quit
End If
On Error Goto 0

WScript.Echo "Processing log entry events for 1 minute..."
WScript.Sleep 60*1000



' Event handler for the LogEntry event. It simply prints out the event.
Sub ClientManagement_LogEntry(Sender, e)
    WScript.Echo e
End Sub
Requirements

Target Platforms: .NET Framework: Windows 10 (selected versions), Windows 11 (selected versions), Windows Server 2016, Windows Server 2022; .NET: Linux, macOS, Microsoft Windows

See Also