OPC Studio User's Guide and Reference
ServerFailedReconnectDelay Property (EasyClientParameters)



OpcLabs.EasyOpcClassicCore Assembly > OpcLabs.EasyOpc.Engine Namespace > EasyClientParameters Class : ServerFailedReconnectDelay Property
Server failed reconnect delay. Number of milliseconds. If the OPC server indicates that vendor specific fatal error has occurred within the server, the server is disconnected, and further connection is retried only after this delay elapses.
Syntax
'Declaration
 
<DataMemberAttribute()>
<ValueRangeAttribute(0, 2147483647)>
Public Property ServerFailedReconnectDelay As Integer
'Usage
 
Dim instance As EasyClientParameters
Dim value As Integer
 
instance.ServerFailedReconnectDelay = value
 
value = instance.ServerFailedReconnectDelay
[DataMember()]
[ValueRange(0, 2147483647)]
public int ServerFailedReconnectDelay {get; set;}
[DataMember()]
[ValueRange(0, 2147483647)]
public:
property int ServerFailedReconnectDelay {
   int get();
   void set (    int value);
}

Property Value

Valid values of this property are in the range from 0 to 2147483647 (Int32.MaxValue).

The default value of this property is 10000.

Exceptions
ExceptionDescription

The value of an argument is outside the allowable range of values as defined by the invoked method.

This is a usage error, i.e. it will never occur (the exception will not be thrown) in a correctly written program. Your code should not catch this exception.

Remarks

The value must be greater than or equal to zero.

This property is used by following client implementations:

Requirements

Target Platforms: .NET Framework: Windows 10 (selected versions), Windows 11 (selected versions), Windows Server 2016, Windows Server 2022; .NET: Linux, macOS, Microsoft Windows

See Also