QuickOPC User's Guide and Reference
ServerTimestamp Property (UADataValue)



OpcLabs.EasyOpcUA Assembly > OpcLabs.EasyOpc.UA Namespace > UADataValue Class : ServerTimestamp Property
The server timestamp associated with the value. In UTC.
Syntax
'Declaration
 
Public Property ServerTimestamp As Date
'Usage
 
Dim instance As UADataValue
Dim value As Date
 
instance.ServerTimestamp = value
 
value = instance.ServerTimestamp
public DateTime ServerTimestamp {get; set;}
public:
property DateTime ServerTimestamp {
   DateTime get();
   void set (    DateTime value);
}
Remarks

When writing, be aware that writing the server timestamp is not supported by some servers, including the OPC Foundation sample server.

In OPC UA PubSub, the server timestamp is only filled in when it is contained in the dataset message. In UADP, this means only when an actual DataValue has been received, which can be either when the DataValue encoding is used, or when DataValue is contained within a Variant.

Requirements

Target Platforms: .NET Framework: Windows 7 with SP1, Windows Server 2012; .NET Core: Linux, Microsoft Windows

See Also

Reference

UADataValue Class
UADataValue Members